Pictures:

Switchgear
Pictures:

 

 

 

 

 

 

 

 

 

 

 

 

 (35) Electric Motors
Columbia, SC

Specifications:

Model

 Motors

Horse Power

Rated 125 HP

Specifications

                

      445TS Frame, Made by Allis, Westinghouse, or US Electric Motors, three phase, 440 volt, 1160 RPM, open drip proof, service factor 1.0

 

 

Switch Gear
(6) Sections

 

Model

Square D Model 4

Volts/Phase

480 Volt 3 Phase

Sections

6

1

B          NEMA 5 starter set for 125 hp full voltage start with circuit breaker, control circuit transformer, and overloads

2

 A         1200 Amp Main Breaker

 B          NEMA 5 starter set for 125 hp full voltage start with circuit breaker, control circuit transformer, and overloads

 C         NEMA 2 starter set for 25 hp full voltage start with circuit breaker, control circuit transformer, and overloads

 D         NEMA 1 starter set for 10 hp full voltage start with circuit breaker, control circuit transformer, and overloads

 

3

 A         1000 amp Main circuit Breaker

 B          NEMA 2 starter set for 20 hp full voltage start with circuit breaker, control circuit transformer, and overloads

 C         NEMA 5 starter set for 125 hp full voltage start with circuit breaker, control circuit transformer, and overloads

4

 A         1200 amp Main Circuit Breaker

 B          NEMA 2 starter set for 25 hp full voltage start with circuit breaker, control circuit transformer, and overloads

 C         NEMA 1 starter set for 10 hp full voltage start with circuit breaker, control circuit transformer, and overloads

 D         NEMA 5 starter set for 125 hp full voltage start with circuit breaker, control circuit transformer, and overloads

  E          Transformer 1 Disconnect

 

5

 A         15 amp Main Circuit Breaker

B          NEMA 5 starter set for 125 hp full voltage start with circuit breaker, control circuit transformer, and overloads

 C         NEMA 2 starter set for 25 hp full voltage start with circuit breaker, control circuit transformer, and overloads

 D        Transformer 5 Disconnect

 

6

 A         1000 amp Main Circuit Breaker

B          NEMA 5 starter set for 125 hp full voltage start with circuit breaker, control circuit transformer, and overloads

 C         NEMA 2 starter set for 25 hp full voltage start with circuit breaker, control circuit transformer, and overloads

 D         Transformer 2 Disconnect

 E          7.5 KVA Transformer

 F          Lighting Panel 2

 

 

Click for Price Inquiry

 

Call Our Sales Department at 800-682-0181

Plant Acquisitions || Specialized Services || Engineering & Construction
ASME Storage || Energy Equipment